NEW SERVICE SPOTLIGHT: PAR4 Measurement Service by Power Assure

Written by Anne Vazquez. Posted in Energy, Featured Post, New Service Spotlight

Tagged: , ,

Published on August 30, 2012 with No Comments

Power Assure, Inc. has introduced the PAR4 Measurement Service designed to measure the true idle and peak power consumption of IT equipment in a rack or an entire data center in order to maximize IT power and space constraints.

Increasing demand for new applications is causing data centers to run out of power, even when the racks or rooms are half full. Data centers are typically provisioned based on the power consumption figures provided by the vendor on the server nameplate label. These figures are designed to be conservative and overstated, leaving much needed power stranded throughout the data center rather than being put to productive use.

The PAR4 Measurement Service provides the accurate power data needed to achieve best practices in data center power management and improve efficiency in energy management.  The PAR4 Measurement Service includes:

  • On-site visit by Power Assure technicians who perform all measurements using the Underwriters Laboratories (UL) tested PAR4 methodology and equipment, based on the UL2640 standard methodology;
  • PAR4 measurements and certificates providing true power usage for every measured server at four power levels, powered off, idle, loaded, and peak, along with the waveform of the power cycle;
  • Periodic access to additional measurements based on a customer’s hardware refresh cycle;
  • Access to Power Assure’s award-winning EM/4 Energy Management Dashboard for rack and server performance monitoring and comparisons; and
  • An upgrade path to EM/4 Capacity Planning, ROI and Lifecycle Analytics.

The PAR4 Measurement Service is immediately available, and Power Assure recommends customers test representative servers. The company offers a 10 pack Measurement Service completed in two days for $2,499, plus expenses.

About Anne Vazquez

Anne Vazquez

Vazquez has been writing about facility management since 1996 when she began working at Today's Facility Manager (TFM) as the magazine's Editorial Assistant. From 2000 to 2005, she continued to work in publishing in another subject field until rejoining TFM's editorial team as Managing Editor in February 2005. In September 2012, she was promoted to Editor of TFM, where she continues to seek out solutions and trends for the magazine's facility management audience. Vazquez can be reached at avazquez@groupc.com.