The Builders Hardware Manufacturers Association (BHMA) announces the publication of three revised American National Standards: ANSI/BHMA A156.3 -2008 for Exit Devices; ANSI/BHMA A 156.4 – 2008 for Door Controls – Closers; and ANSI/BHMA A156.16 – 2008 for Auxiliary Hardware.

ANSI/BHMA A156.3 for Exit Devices
This standard establishes requirements for exit devices and trim, automatic and self-latching flush bolts, removable mullions, coordinators and carry-open bars. Among the changes to ANSI/BHMA A156.3, the updated standard includes tightening the operational key torque value to 12 in-lbf; adding electrified exit device functions; and adding definitions for dogging, electric dogging, mullions and multipoint exit devices and unlatches. This publication is an update of an earlier 2001 version of the standard.

ANSI/BHMA A156.4 for Door Controls – Closers
This standard contains requirements for door closers surface mounted, concealed in the door, overhead concealed, and concealed in the floor. Also included are pivots for floor closers. Whole scale reformatting was done primarily to reduce cross references and clarify test sequences for each type of closer. Changes to ANSI/BHMA A156.4 include improving floor marking template diagrams; clarifying the door weight table by showing ranges; revising leakage failure criteria; adding a dead stop test procedure based on A156.8 for stops and holders; and clarifying the requirements for range of closing motion. This publication is an update of an earlier 2000 version of the standard.

ANSI/BHMA A156.16 for Auxiliary Hardware
This standard establishes requirements for auxiliary hardware. Among the changes to ANSI/BHMA A156.16, the updated standard includes updated product type illustrations; revised shower curtain rod test requirements and moving the location of the door stop in the cycle test to across the middle hinge. This publication is an update of an earlier 2002 version of the standard.

About Heidi Schwartz

Heidi Schwartz

Schwartz joined Group C Media in April 1989 as managing editor of Today's Facility Manager (TFM) magazine (formerly Business Interiors) where she was subsequently promoted to editor/co-publisher of the monthly trade magazine for facility management professionals. In September 2012, she took over the newly created position of internet director for TFM's parent company, Group C Media, where she is charged with developing content and creating online strategies for TFM and its sister publication, Business Facilities. Schwartz can be reached at schwartz@groupc.com.